CH CH24L3125C
MFG #CH24L3125C
SKU #3808549
Product description
CH CH24L3125C 125AMP MAIN LUG (24)CIRCUIT 208Y/120VAC 3PHASE 4WIRE COPPER BUS TYPE CH LOADCENTER NEMA1
EATON Main Lug Loadcenter, 3-Phase Standard, 208Y/120 VAC, 240 VAC, 125 A, 24 Pole, 35 kA Interrupt, 24 Circuits, CH Breaker, Plug-On Breaker Mounting, 4-Wire Wiring Configuration, 24 Spaces, 4/0 to 1 AWG Wire, Flush Mount, NEMA 1, C Enclosure Box, Metal Housing, 14.31 in W x 5.19 in D x 21 in H
EATON Main Lug Loadcenter, 3-Phase Standard, 208Y/120 VAC, 240 VAC, 125 A, 24 Pole, 35 kA Interrupt, 24 Circuits, CH Breaker, Plug-On Breaker Mounting, 4-Wire Wiring Configuration, 24 Spaces, 4/0 to 1 AWG Wire, Flush Mount, NEMA 1, C Enclosure Box, Metal Housing, 14.31 in W x 5.19 in D x 21 in H
- Electrical Assemblies, Panels and EOEM and Power Distribution Applications
- EATON Main Lug Loadcenter, 3-Phase Standard, 208Y/120 VAC, 240 VAC, 125 A, 24 Pole, 35 kA Interrupt, 24 Circuits, CH Breaker, Plug-On Breaker Mounting, 4-Wire Wiring Configuration, 24 Spaces, 4/0 to 1 AWG Wire, Flush Mount, NEMA 1, C Enclosure Box, Metal Housing, 14.31 in W x 5.19 in D x 21 in H
- Suitable for use as service equipment when a circuit breaker is used as a main breaker
The main breaker is back-fed and requires hold down bracket kit catalog number CH125RB
Suitable for use as service equipment when not more than six service disconnecting mains are provided
Overhead/underground feed applications
6-2/0 AWG wire size range copper/aluminum at 60 or 75 deg C for main lugs
Furnished with hub closure plates
- LOADCENTER LUG MAIN 125A 24 35KA 24 CH C
- Product Catalog Page(s)
Specification Sheet
- UL 50/67|PROP65: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer and Bisphenol A (BPA) which is known to the State of California to cause birth defects or other Reproductive harm. For more information go to www.P65Warnings.ca.gov
- Brand:Â Eaton Cutler Hammer DistributionAmperage Rating:Â 125 AApplication:Â Elec Assemblies, Panels & EOEM - Electrical Assemblies, Panels and EOEMsCable Size:Â #1-4/0 AWGCircuit Breaker Type:Â CHCountry of Origin:Â USEnclosure:Â NEMA 1Interrupt Rating:Â 35 kAICNumber Of Feeders:Â Overhead or undergroundNumber Of Spaces:Â 24Phase:Â Three-phaseSize:Â CSpecial Features:Â StandardType:Â Main lug loadcenterWiring Configuration:Â Four-wireIDW2 Image1 URL:Â https://ideadigitalasset.com/DAMRoot/Original/11211/10964_3X6DGZW5I2FOEHSQ.jpg